Artigo em Inglês | MEDLINE | ID: mdl-38044882

RESUMO

BACKGROUND: Fogging and staining of a laparoscope lens negatively impact surgical visualization. We hypothesized that the disposable hot pack could not only warm but also clean laparoscopes. Hence, this study verified and developed the disposable hot pack with anti-fogging and cleaning function. MATERIAL AND METHODS: The laparoscope was inserted into a swine abdominal cavity for five minutes. Then, the laparoscopic tip was heated with 65 °C saline or the folded disposable hot pack with nonwoven fabric coated surfactant for ten seconds (n = 15). Also, a laparoscopic tip with dirt was wiped with the prototype or conventional gauze for 10 s (n = 10). The dirt, fogging, and temperature of the laparoscopic tip were respectively evaluated after the laparoscope was inserted into the abdominal cavity. RESULTS: The laparoscopic tip temperature five minutes after insertion into the abdominal cavity was similar (31.1 °C vs 31.2 °C, p = 0.748) and there was no fogging in both methods. The conventional gauze had significantly less temperature of the laparoscopic tip after cleaning and higher fogging occurrence than the prototype (29.5 °C vs 34.0 °C, p < 0.001, 30% vs 0%, p = 0.030, respectively), although there was no dirt left after both methods. CONCLUSION: The disposable hot pack has a strong potential as an anti-fogging and cleaning device for use during laparoscopic surgery.

2.
Minim Invasive Ther Allied Technol ; 32(2): 56-61, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36576090

RESUMO

BACKGROUND: During laparoscopic surgery, visualization is fogged due to the influence of temperature. Fogging on the laparoscopic lens heightens the difficulty of the procedure. Therefore, the aim of this study was to analyse thermodynamics in laparoscopy. MATERIAL AND METHODS: A temperature sensor was attached to the laparoscopic tip and the abdominal cavity of five swine under general anaesthesia. The laparoscope was inserted into the abdominal cavity for five minutes after heating its tip with 65 °C saline for 10-300 s. The defogged laparoscope was wiped at room temperature for 10-300 s. Then, the laparoscope was inserted into the abdominal cavity for five minutes. RESULTS: The temperature five minutes after insertion was similar for the 10-300 s heating durations (approximately 32.0 °C). There was no fogging when the laparoscope was wiped for 10-30 s. Two fogging events occurred when it was wiped for 60 s (temperature difference: -3.5 °C, -4.6 °C). Five fogging events were observed immediately after insertion when it was wiped for 300 s. CONCLUSION: This study showed that the heating time was more than ten seconds to prevent fogging. We found that fogging occurred when the laparoscopic tip temperature was 3.5 °C lower than the abdominal cavity temperature.


Assuntos
Laparoscopia , Lentes , Animais , Suínos , Laparoscopia/métodos , Laparoscópios , Temperatura , Temperatura Corporal
3.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 66(1): 33-41, 2010 Jan 20.
Artigo em Japonês | MEDLINE | ID: mdl-20145362

RESUMO

In infant CT scans, it is important to minimize radiation exposure without lowering the quality of the diagnosis. Therefore, appropriate parameters for infant CT scan should be considered at each institute. In order to determine parameters for infant body CT, we measured the physical characteristics of our current CT machine and evaluated scan parameters as S.D. below 10 on the basis of literature recommendations, which say that we should adopt S.D. of the liver when treated with a radiation exposure dose in an adult abdominal CT scan. As a result, the ideal parameters were 90 kV tube voltage, ultra fast detail resolution, B kernel, and Eff.mAs value calculated from patient body width. Infant body CT scans with the mentioned parameters resulted in an S.D. below 10, and this is thought to be applicable to further examinations.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Pré-Escolar , Feminino , Humanos , Masculino , Imagens de Fantasmas , Doses de Radiação